XL-GDB-101E

Catalogue number: XL-GDB-101E

XL-GDB-101E

Convertor / modem E1 via G.SHDSL, two-wire

Modem / convertor E1 line to single-pair wires G.SHDSL connection with range 8,4 km (2Mbps/3,6km@24AWG). Easy switch-board connection over two-wire circuit. Interface G.703 E1, Nx64kbps, max. 2,304Mbps, interface 120 ohm, RJ-45.


 

The XL-GDB SHDSL access system provides high-speed data access over single-pair copper wires. It can transmit up to 2.304 Mbps V.35 or Ethernet signal without a repeater for more than 7km (24 AWG line) at a Bit Error Rate of less than 10-7. Using SHDSL transmission technology, the XL-GDB SHDSL network access system allows fiber quality transmission on a single pair of copper wire. Using lower gauge larger copper wire may allow you to attain greater distances.

 

XL-GDB desktop SHDSL modem is part of the XtendLan SHDSL access system. Used in conjunction with the XL-GDB shelf type CO (Central Office) line card or desktop SHDSL modem, the unit provides repeater less data transport of up to 2.304 Mbps, over a single pair of unconditioned copper wire. Also models with 2-pair transmitions provide rates up to 4.096 Mbps. The rate is automatically adjusted to synchronize at specified rates, corresponding to the distance between the local and remote units. For instance, under the E1 transmission specification, the data rate is software selectable at any of the available Nx64 kbps rates where N is from 3 to 32. More parameters are presented in manual.

 

Features

  • One of the equipment with best transmission capability in xDSL series of products
  • Shelf type equipment for “Star” topology networking
  • Standalone type equipment for “bus” topology (including point-to-point) networking
  • Centralized Network Management System in Shelf type equipment
  • LCD panel on standalone model for handy operation
  • Upgrade of software and firmware can be done by download
  • On-line performance (line error) monitoring
  • Self-test, Loop-back and QRSS testing features for on-site trouble shoot


Specification 

MDSL Loop
Number of copper wire
Line code
Line Rate
Line Impedance
Bandwidth
Transmit power
Reach
Connector
One pair
CAP
144-2064Kbps
135 ohms
4-400 KHz
7.4-13dBm
2.7-60Km|0,4mm or 26AWG)
RJ-48
 
E1 Interface
Standard Compliance
Line code
Frame format
Line rate Data rate
Line Impedance
Connector
ITU-TG703/G 704
HDB3
Framed or Unframed
2 048+/-50PPM
N*64K 1<=N<=32120 or 75 ohms
DB-15/BNC
 
High Speed Data Interface
Data Rate Interlace
N'64K. 1<=N<=32
V.35, X 21, EIA-350, RS-449
 
Ethernet Interface
Remote Bridge
IEEE 802 3 Compatible
UTPLAN(10Base)
10,000 Address LAN Table
256 frames buffer
15,000 PPSFiltering
Automatic LAN Table Learning and aging
 
Power Requirement
-36 ~72 VDC for shelf type
-36 ~72 VDC or 90-260 VAC for standalone type
 
System Management
LCD Panel. VT-100 ASCII Terminal, GUI based
 
Safety and EMI/EMC
FCC Part 68, FCC Part15,CE
 
Environment
Temperature
Humidity
0-60°C
 5%-95%